FAQ 8: Can SP-CRD be applied in a return system that is experiencing backpressure problems?

Yes. Consider the 150 psig distribution line outlined in FAQ #6, when nozzle #03 is used, the CRD is able to discharge condensate at a rate of 41lb/hr under the minimum ambient condition. At 150psig operating pressure, assuming the backpressure build up to as much as 80%, i.e. 120psig, the CRD is still able to effortlessly discharge condensate at a rate of 48lb/hr at the reduced effective pressure. The reason is that the CRD fitted with nozzle #03 has a design capacity of 106 lb/hr.